Node unclean offline pacemaker.
HA cluster - Pacemaker - OFFLINE nodes status.
Node unclean offline pacemaker These are recommended but not required to fix the corruption problem. service Authenticating the cluster nodes: Install pacemaker in all the 3 nodes: $ sudo apt-get install pacemaker pacemaker-cli-utils \ resource-agents fence-agents crmsh Enable pacemaker - the cluster resource-manager - and activate it: Mon Feb 24 01:40:53 2020 by hacluster via crmd on clubionic01 3 nodes configured 0 resources configured Node clubionic01: UNCLEAN (offline) Node After stopping pacemaker on all nodes, start it up using the following command: systemctl start pacemaker ; OR crm cluster start Pacemaker will cleanup failed messages during startup. crmd process continuously respawns until its max respawn count is reached. keep pcs resources always running on all hosts. 4. Background: - RHEL6. Running the pcs status command shows that node z1. Unable to communicate with pacemaker host while authorising. . When I run the pcs status command on both the nodes, I get the message that the other node is UNCLEAN (offline). Previous message (by thread): [Pacemaker] Problem with state: UNCLEAN (OFFLINE) Next message (by thread): [Pacemaker] Problem with state: UNCLEAN (OFFLINE) Messages sorted by: Create a cluster with 1 pacemaker node and 20 nodes running > pacemaker_remote. The fence agent standard provides commands (such as off and reboot) that the cluster can use to fence nodes. Red Hat Enterprise Linux (RHEL) 7、8、9 (High Availability Add-On 使用) root@node01:~# crm status noheaders inactive bynode Node node01: online fence_node02 (stonith:fence_virsh): Started Node node02: UNCLEAN (offline) Sometimes you start your corosync/pacemaker stack, but each node will report that it is the only one in the cluster. com > One of the nodes appears UNCLEAN (offline) and other node appears (offline). conf and restart corosync on all > other nodes, then run "crm_node -R <nodename>" on any one active node. Especially any SAP Hana Secondary should be in SBD can be operated in a diskless mode. > 3. The example commands in this document will use: CentOS 7. 3). node 1: mon0101 is online and mon0201 is offline node 2: mon0101 is offline and mon0201 is online . We would like to show you a description here but the site won’t allow us. Configure a fence agent to run on the pacemaker node, which can power off > the pacemaker_remote nodes. Transitions¶. Versions: Environment OS: Ubuntu 18. srv. [root@fastvm-rhel-8-0-23 ~]# pcs status Node fastvm-rhel-8-0-24: OFFLINE Node cluster1: UNCLEAN (offline) Online: [ cluster2 ] Needs to be root for Pacemaker. This Support Knowledgebase provides a valuable tool for SUSE customers and parties interested in our products and solutions to acquire information hi. however, once the standby node is fenced the resources are started up by the cluster. One of the controller nodes had a very serious hardware issue and the node shut itself down. Generic case: A node left the corosync membership due to token loss. 168. com Stack: corosync Current DC: nodedb02. It is linked to the top directory. history. use_mgmtd: yes. Once the patching is done, maybe even a reboot, on the patched node the cluster is started again with crm cluster start This will make the node available again for SAP Applications. Created attachment 1130590 pacemaker. On each node run: crm cluster start Pacemaker and DLM should also be pacemaker on the survivor node when a failover occurs). failed to authenticate cluster nodes using pacemaker on centos7. 4-e174ec8) - partition WITHOUT quorum Last updated: Tue May 29 16:15:55 2018 Last change: On Tue, 2019-07-09 at 12:54 +0000, Michael Powell wrote: > I have a two-node cluster with a problem. 2; Installed HA tools on both servers: yum install pacemaker pcs (It will include install corosync) On both servers: passwd hacluster Set same password for cluster. 13-10. 44 Resource manager that can start and stop resources (like Pacemaker) Messaging component which is responsible for communication and membership (like Corosync or Heartbeat) Optionally: file synchronization which will keep filesystems equal at all cluster nodes Node nginx1: UNCLEAN (offline) All Pacemaker nodes stuck UNCLEAN (offline) after corosync update. 102. Corosync is happy, pacemaker says the nodes are online, but the cluster status still In my configuration I use bindnetaddr with the ip address for each host. Disclaimer. 在测试HA 的时候,需要临时增加硬盘空间,请硬件同事重新规划了虚拟机的配置。 测试过程中出现了一个奇怪的问题两边node 启动了HA 系统后,相互认为对方是损坏的。 crm_mon 命令显示node95 UNCLEAN (offline)node96 online另一个节点 node95 则相反,认为node96 offline unclean没有办法解决,即便是重装了HA 系统 9. Also the SLES11sp4 node was brought up first and the current DC (Designated HA cluster - Pacemaker - OFFLINE nodes status. 15. On node I pcs is running: [root at sip1 ~]# pcs status Cluster name: sipproxy Last updated: Thu Aug 14 14:13:37 2014 Last change: Sat Feb 1 20:10:48 2014 via crm_attribute on sip1 1. el9-ada5c3b36e2) - partition with quorum * Last updated: Fri Mar 25 09:18:32 2022 * Last change: Fri Mar 25 09:18:11 2022 by root via cibadmin on node01. 16-4. another thing. Contains the output of the crm_mon command. 1 virtual machines. node2: bindnetaddr: 192. After a stonith action against the node was initiated and before the node was rebooted, the node rejoined the corosync DHCP is not used for either of these interfaces. conf: If set, this will make each starting node wait until it sees the other before gaining quorum for the first time. ver: 0. But, I found a problem with the unclean (offline) state. Start pacemaker on all cluster nodes. 4. [17625]: error: Input I_ERROR received in state S_STARTING from reap_dead_nodes pacemaker-controld[17625]: notice: State transition S_STARTING -> S_RECOVERY pacemaker-controld[17625]: warning: Fast-tracking pcs ステータスがノードを UNCLEAN と報告します。 クラスターノードに障害が発生し、pcs ステータスは、リソースが開始または移動できない UNCLEAN 状態であると表示します。 Environment. > > Node pilotpound: UNCLEAN (offline) > Node powerpound: standby > > However, when putting one node into standby, the resource fails and is fenced. The initial state of my One of the nodes appears UNCLEAN (offline) and other node appears (offline). SLES114: rcopenais start SLES12+: systemctl start pacemaker. So, repeating deleting and create same resource (changing resource id), sometimes, it seems Started but, after rebooting the node which started, it becomes UNCLEAN state after that, it becomes STOP though rest node is online. replies . Using two nodes: node1: 192. I went in with sudo crm configure edit and it showed the configuration Issue. 1. A fence agent or fencing agent is a stonith-class resource agent. 18 Corosync version: 2. My problem is that in my case, Node1 should be primary, meaning it should be always used whenever it is online. > 2. - Red Hat Customer Portal Nodes show as UNCLEAN (offline) Current DC: NONE. cib: Bad global update Errors in /var/log/messages: In this case, one node had been upgraded to SLES11sp4 (newer pacemaker code) and cluster was restarted before other node in the cluster had been upgraded. com Mon Aug 18 11:33:18 CEST 2014. Contains all cluster package versions on your nodes. log excerpt When I bring 2 nodes of my 3-node cluster online, 'pcs status' shows: Node rawhide3: UNCLEAN (offline) Online: [ rawhide1 rawhide2 ] which is expected. ?* Because a log file was big, I registered the same contents with Bugzilla. This is Pacemaker 1. On each node run: Pacemaker and DLM should also be updated to allow for the larger ringid. What do people from medieval times use to drink water? started 2011-06-17 23:22:44 UTC. If this happens, first make sure that the hosts are reachable on the network: Pacemaker 集群中的节点被报告为 UNCLEAN。 Solution In Progress - Updated 2023-10-25T00:16:42+00:00 - Chinese . Pacemaker automatically generates a status section in the CIB (inside the cib element, at the same level as configuration). > It shouldn't be, but everything in HA-land is complicated :) > >> Trivial test two node cluster (two_node is Issue. I have a cluster with 2 Nodes running on different subnets. service pacemaker-controld will fail in a loop. I'm building a pacemaker practise lab of two nodes, using CentOS 7. None is used when only 1 interface specified How do I obtain quorum after rebooting one node of a two-node Pacemaker cluster, when the other node is down with a hardware failure? One cluster node is down, and resources won't run after I rebooted the other node. description. A transition is a set of actions that need to be taken to bring the cluster from its current state to the desired state (as expressed by the configuration). 04. If you want a resource to be able to run on a node even if its health score would otherwise prevent it, set the resource’s allow-unhealthy-nodes meta-attribute to true (available since 2. In this case, one node had been upgraded to [Pacemaker] Nodes appear UNCLEAN (offline) during Pacemaker upgrade to 1. Previous message: [Pacemaker] Error: cluster is not currently running on this node Next message: [Pacemaker] Error: cluster is This additionally leads to fence of the the node experiencing a failure: The "lvmlockd" pacemaker resource enters a "FAILED" state when the lvmlockd service is started outside the cluster. world * 2 nodes configured * 1 resource instance . Needs to be root for Pacemaker. a filesystem mount and a filesystem bind that are managed by pacemaker. 8. All Pacemaker nodes stuck UNCLEAN (offline) after corosync update. pcs status 报告节点为 UNCLEAN; 集群节点发生故障,pcs status 显示资源处于UNCLEAN 状态,无法启动或移动 Stack Overflow for Teams Where developers & technologists share private knowledge with coworkers; Advertising & Talent Reach devs & technologists worldwide about your product, service or employer brand; OverflowAI GenAI features for Teams; OverflowAPI Train & fine-tune LLMs; Labs The future of collective knowledge sharing; About the company Visit the blog Post by renayama19661014 Possibly this may be a problem of ccm. 3. If a node is down, resources do not start on node up on pcs cluster start; When I start one node in the cluster while the other is down for maintenance, pcs status shows that missing node as "unclean" and the node that is up won't gain quorum or manage resources. 1 time online, 1 time offline. When Node1 goes offline, Node2 is used vice-versa. I tried deleting the node id, but it refused. Care should be taken, that any SAP Application is started correctly and is working properly on the returning node. 7 Parshvi parshvi. Status¶. 2 server Pacemaker version: 1. Power on all the nodes so all the resources start. The DRBD version of the kernel module is 8. [root@rh91-b01 ~]# cat /etc/redhat-release Red Hat Enterprise L CentOS Stream 9 Pacemaker Set Fence Device. Corosync is happy, pacemaker says the nodes are online, but the cluster status still says both nodes are "UNCLEAN (offline)". com (version 1. Create a place to hold an authentication key for use with pacemaker_remote: Fri Jan 12 12:42:21 2018 by root via cibadmin on example-host 1 node configured 0 resources configured Node example-host: UNCLEAN (offline) No active resources Daemon Status: Nodes show as UNCLEAN (offline) Current DC: NONE. This document (000019604) is provided subject to the disclaimer at the end of this document. On the nodes with IP, corosync is connected and green (Pacemaker is not successfull). Edit: bindnetaddr his is normally the network address of the interface to bind to. Following are the steps: Step 1: When we create kernel panic (on Node01) with the command “echo 'b' > /proc/sysrq-trigger” or “echo 'c' > /proc/sysrq-trigger” on the node where the resources are running, then the cluster detecting the change but unable to start any resources (except Hi All, We have confirmed that it works on RHEL9. Which is expected. For each pacemaker_remote node, configure a service > constrained to run only on that node. Pacemaker tried to power it back on via its IPMI device but the BMC refused the power-on command. To describe it better: Node1 and Node2 are online -> Node1 is being used; Node1 goes offline -> Node2 is being used automatically while Pacemaker/Corosync was running. el7-44eb2dd) - In case something happens to node 01, the system crashes, the node is no longer reachable or the webserver isn’t responding anymore, node 02 will become the owner of the virtual IP and start its webserver to provide the same services as 在测试HA 的时候,需要临时增加硬盘空间,请硬件同事重新规划了虚拟机的配置。测试过程中出现了一个奇怪的问题两边node 启动了HA 系统后,相互认为对方是损坏的。 crm_mon 命令显示node95 UNCLEAN (offline)node96 online另一个节点 node95 则相反,认为node96 offline unclean没有办法解决,即便是重装了HA 系统也是 When the primary node is up before the second node it fences it after a certain amount of time has past. To initialize the corosync config file, execute the following pcs command NONE 1 node and 0 resources configured Node example-host: UNCLEAN (offline) Full list of resources: PCSD Status: example-host: Online Daemon Status: corosync msnode1:~ # systemctl stop pacemaker msnode2:~ # crm status Stack: corosync Current DC: msnode2 (version 1. - wait_for_all in corosync. This document (000019683) is provided subject to the disclaimer at the end of this document. This happens on Ubuntu 22. You are currently viewing LQ as a guest. I tried deleting the node name, but was told there's an active node with that name. PCSD Status shows node offline whilepcs status shows the same node as online. On each node run: crm cluster start Pacemaker and DLM should also be PCSD Status shows node offline whilepcs status shows the same node as online. txt file which is node specific. Once the rebooted node re-joins the cluster, it > Im using a pacemaker/corosync 2 node cluster on an CentOS 6. This is particularly useful for node health agents, to allow them to detect when the node becomes healthy again. After re-transmission failure from one node to another, both node mark each other as dead and does not show status of each other in crm_mon. First, make sure you have first created an ssh-key for root on the first node: [root@centos1 . Cluster name: ha_cluster Cluster Summary: * Stack: corosync * Current DC: node01. The configuration files for DRBD and Corosync do not contain anything interesting. [root@ha1 log]# pcs status Cluster name: mycluster WARNING: no stonith devices and stonith-enabled is not false Last updated: Wed Dec 24 21:30:44 2014 Last change: Wed Dec 24 21:27:44 2014 Stack: cman Current DC: ha1p - partition with quorum Version: 1. By joining our community you will have the ability to post topics, receive our newsletter, use the advanced search, subscribe to threads Online: [ data-master ] OFFLINE: [ data-slave ] Node 2 (data-slave) Last updated: Tue Feb 25 19:25:10 2014 Last change: Tue Feb 25 18:47:17 2014 by root via cibadmin on data-master Stack: classic openais (with plugin) Current DC: data-slave - partition WITHOUT quorum Version: 1. Find out which node is active in the PCS cluster - CentOS 7 [Pacemaker] Error: cluster is not currently running on this node emmanuel segura emi2fast at gmail. crm status shows all nodes "UNCLEAN (offline)" 2. The two nodes that I have setup are ha1p and ha2p. 11-97629de 2 Nodes configured 0 Resources configured Node ha2p: UNCLEAN (offline) Online: [ ha1p ] Full Hi All I am learning sentinel 7 install on SLES HA, now I have configure HA basic function,and set SBD device work finebut I restart them to verify all. On the nodes with DNS, corosync is failed and Pacemaker is connected and successfull). Fence Agents¶. 4 as the host operating system Pacemaker Remote to perform resource management within guest nodes and remote nodes KVM for virtualization libvirt to manage guest nodes Corosync to provide messaging [Pacemaker] Problem with state: UNCLEAN (OFFLINE) Digimer lists at alteeve. A key concept in understanding how a Pacemaker cluster functions is a transition. 101. In this mode, a watchdog device is used to reset the node in the following cases: if it loses quorum, if any monitored daemon is lost and not recovered, or if Pacemaker decides that the node requires fencing. Hi! After some tweaking past updating SLES11 to SLES12 I build a new config file for corosync. The SSH STONITH agent is using the same After some tweaking past updating SLES11 to SLES12 I build a new config file for corosync. world (version 2. This ensures that you can use identical instances of this configuration file across all your cluster nodes, without having to How to remove a node from HA pacemaker cluster. 1beta. When the network cable is pulled from node A, corosync on node A binds to 127. #User to run aisexec as. If node1 is the only node online and tries to fence itself, it only tries the level 1 stonith device. The other node fails to stop a resource but does not get fenced. If stonith level 1 fails, it is retried repeatedly, and level 2 is never tried. There is also the sysinfo. 1. Environment. 4 to provide a loadbalancer-service via pound. What I see is that the master node switches to UNCLEAN - Offline, the master resource stops running (crm_mon shows only the slave node running) and then it just sits there until the master node finishes booting. In addition, the same problem may be already reported. SUSE Linux Enterprise High Availability includes the stonith command line tool, an extensible interface for remotely powering down a node in the cluster. el7_3. ; At this point, all resources owned by the node transitioned into UNCLEAN and were left in that state even though the node has SBD as a second-level fence device defined. SUSE Linux Enterprise High Availability Extension 15 SP1 SUSE Linux Enterprise High Cluster fails to start after cluster restart. The two nodes have pacemaker installed and FW rules are enabled. [17625]: error: Input I_ERROR received in state S_STARTING from reap_dead_nodes pacemaker-controld[17625]: notice: State transition S_STARTING -> S_RECOVERY pacemaker-controld[17625]: warning: Fast-tracking When a cluster node shuts down, Pacemaker’s default response is to stop all resources running on that node and recover them elsewhere, even if the shutdown is a clean shutdown. Red Hat Enterprise Linux DevOps & SysAdmins: pacemaker node is UNCLEAN (offline)Helpful? Please support me on Patreon: https://www. el7-44eb2dd) - The cluster detects failed node (node 1), declares it “UNCLEAN” and sets the secondary node (node 2) to OFFLINE: [ prihana ] Full list of resources: res_AWS_STONITH (stonith:external/ec2): with the AWS Management Console or AWS CLI tools and start Pacemaker (if it’s not enabled by default). 'pcs stonith confirm rawhide3' then says: Node: rawhide3 confirmed fenced so I would now expect to see: Online: [ rawhide1 rawhide2 ] OFFLINE: [ rawhide3 ] but instead I The document exists as both a reference and deployment guide for the Pacemaker Remote service. com is offline and that the resources that had been running on z1. Red Hat Enterprise Linux Server 7 (with the High Availability Add-on) When I login into the "Radhat High Availability" gui, I can see 6 nodes instead of three: 3 Nodes with IP and 3 Nodes with DNS. 11 and that of the drbd-utils is 9. 2 and Corosync 3. We are using SLES 12 SP4. The machine centos1 will be our current designated co-ordinator (DC) cluster node. cib: One node in the cluster had been upgraded to a newer version of pacemaker which provides a feature set greater than what's supported on older version. After starting pacemaker. name: pacemaker} totem {#The mode for redundant ring. If I start Not so much a problem as a configuration choice :) There are trade-offs in any case. ca Fri Jun 8 13:56:17 UTC 2012. corosync. The status is transient, and is not stored to disk with the rest of the CIB. Pacemaker and Corosync require static IP addresses. 2-4. example. 9. ssh]# ssh-keygen -t rsa Generating public/private rsa key pair. On pcs node standby, if they are not shutdown The first command shows that DRBD is active on the first node, but not active on the second node. You may also issue the command from any node in cluster by specifying the node name instead of "LOCAL" Syntax: sbd -d <DEVICE_NAME> message <NODENAME> clear Example: sbd -d /dev/sda1 message node1 clear Once the node slot is cleared, you should be able to start clustering. After I did all the things well, I reboot node1 to test high availability. When I set 2 node HA cluster environment, I had some problems. We have observed few things from the today testing. If I start all nodes in the cluster except one, those nodes all show 'partition WITHOUT quorum' in pcs status and HA cluster - Pacemaker - OFFLINE nodes status. Pacemaker attempts to start the IPaddr on Node A but it Compares files that should be identical on all nodes. When I configure the cluster with Dummy with pcs, the cluster is successfully configured and can be stopped properly. service Though, after two node rebooted, cluster state quite correct (as Active) But I don't know why resource always becomes Stop. 0. com]#pcs status Cluster name: clustername Last updated: Thu Jun 2 11:08:57 2016 Last change: Wed Jun 1 20:03:15 2016 by root via crm_resource on nodedb01. Note: this can be due to the second node being stopped or in standby. service systemctl start pcsd. IP 1. On both servers: systemctl enable pcsd. patreon. The cluster fences node 1 and promotes the secondary SAP HANA database (on node 2) to take over as primary. pacemaker node is UNCLEAN (offline) 2. 17 at gmail. 2. txt. I use crm_mon command to check nodeI find node02 show unclean(Off Configure Pacemaker for Remote Node Communication. 15-11. Cluster name: democluster WARNINGS: No stonith devices and stonith-enabled is not false Cluster Summary: * Stack: unknown (Pacemaker is running) * Current DC: NONE * Last updated: Sun May 12 05:21:38 2024 on node1 * Last change: Sun May 12 05:21:21 2024 by hacluster via hacluster on node1 * 3 nodes configured * 0 resource instances configured Node In theory, this issue can happen on any platform if timing is unlucky, though it may be more likely on Google Cloud Platform due to the way the fence_gce fence agent performs a reboot. Can not start PostgreSQL replication resource with Corosync/Pacemaker. 8-77ea74d) - partition WITHOUT quorum Last updated: Tue Jun 25 17:44:26 2019 Last change: Tue Jun 25 17:38:20 2019 by hacluster via cibadmin on msnode1 2 nodes configured 2 resources configured Online: [ msnode2 ] OFFLINE: [ msnode1 During pcs cluster stop --all, one node shuts down successfully. 3 pcs version: 0. The secondary server didn't have the new VM data/settings yet, [Linux-HA] Node UNCLEAN (online)' (Questions and Answers) 9 . For example: node1: bindnetaddr: 192. > After a update with yum the updatet node is not able to work in the cluster again. user: root} service {#Default to start mgmtd with pacemaker. 9-2db99f1 2 Nodes configured, 2 expected votes 0 Resources 15. 0. This is for I'm using Pacemaker + Corosync in Centos7 Create Cluster using these commands: When I check the status of cluster I see strange and diffrent behavior between pcs status reports nodes as UNCLEAN; cluster node has failed and pcs status shows resources in UNCLEAN state that can not be started or moved; Environment. DC appears NONE in # yum install -y pacemaker corosync pcs crmsh Also did load balancer with HAProxy. Exempting a Resource from Health Restrictions¶. As with other resource agent classes, this allows a layer of abstraction so that Pacemaker doesn’t need any knowledge about specific fencing technologies – that knowledge is isolated The entire time, the partition says it has quorum. 3. 16. Document The cluster detects failed node (node 1), declares it “UNCLEAN” and sets the secondary node (node 2) to status “partition WITHOUT quorum”. Contains a copy of the Corosync configuration file. The primary node currently has a status of "UNCLEAN (online)" as it tried to boot a VM that no longer existed - had changed the VMs but not the crm configuration at this point. But, when the standby node remains down and out of the cluster I can't seen to manage any of resources with the pcs commands A node rebooted, On 12/06/2017 08:03 PM, Ken Gaillot wrote: > On Sun, 2017-12-03 at 14:03 +0300, Andrei Borzenkov wrote: >> I assumed that with corosync 2. group: root. When node1 When you unplug a node's network cable the cluster is going to try to STONITH the node that disappeared from the cluster/network. I have since modified the configuration and synced data with DRBD so everything is good to go except for pacemaker. Nodes are reported as UNCLEAN (offline) Current DC shows as NONE # pcs status Cluster name: my_cluster Status of pacemakerd: 'Pacemaker is running' (last updated 2023-06-27 12:34:49 -04:00) Cluster Summary: * Stack: corosync * Current DC: NONE Welcome to LinuxQuestions. When I forced one of the old VMs down, it triggered a failover. In a Pacemaker cluster, the implementation of node level fencing is STONITH (Shoot The Other Node in the Head). > crmd process continuously respawns until its max respawn count is reached. 164 Description I have 2 servers running in cluster (server1, server2). That config file must be initialized with information about the cluster nodes before pacemaker can start. For an overview of the available options, run stonith --help or refer to the man page of stonith for more information. 1 and pacemaker believes that node A is still online and the node B is the one offline. They both communicate but I have always one node offline. After an outage, it happens that a controller has no resources, or can't join the cluster [root@controller1 ~]# pcs status Cluster name: tripleo_cluster WARNING: no stonith devices and stonith-enabled is not false Stack: corosync Current DC: controller1 (version 1. Checking with sudo crm_mon -R showed they have different node ids. 2 LTS with Pacemaker 2. server1 is marked as UNCLEAN and offline. Galera cluster - cannot start MariaDB (CentOS7) 0. com are LOCKED while the node Get a virtual cloud desktop with the Linux distro that you want in less than five minutes with Shells! With over 10 pre-installed distros to choose from, the worry-free installation life is here! Whether you are a digital nomad or just looking for flexibility, Shells can put your Linux machine on the device that you want to use. x quorum is maintained by corosync and >> pacemaker simply gets yes/no. crm_mon. Apparently this is more complicated. 4 - cman-cluster with pacemaker - stonith enabled and working - resource monitoring failed on node 1 => stop of resource on node 1 failed => stonith off node 1 worked - more or less parallel as resource is clone resource resource monitoring failed on node 2 => stop of resource on node 2 failed => stonith of node 2 failed as You want to ensure pacemaker and corosync are stopped on the > node to be removed (in the general case, obviously already done in this > case), remove the node from corosync. English; Chinese; Japanese; Issue. com/roelvandepaarWith thanks & praise to G Problem with state: UNCLEAN (OFFLINE) Hello, I'm trying to get up a directord service with pacemaker. block Corosync communication ( expected behaviour: Nodes cant see each other, one node will try to STONITH the other node, remaining node shows stonithed node offline unclean, after some seconds offline clean; Recently, I saw machine002 appearing 2 times. 1; node2: 192. nodedb01. The section’s structure and contents are internal to Pacemaker and subject to change from release to release. [17625]: error: Input I_ERROR received in state S_STARTING from reap_dead_nodes pacemaker-controld[17625]: notice: State transition S_STARTING -> S_RECOVERY pacemaker-controld[17625]: warning: Fast-tracking 1. org, a friendly and active Linux Community. xni ohnizi pdnl hmcuxma kzph auktqlc gkquk hno yexedfk diyw